flutter_ppg 0.2.0
flutter_ppg: ^0.2.0 copied to clipboard
A Flutter package for camera-based PPG (Photoplethysmography) signal processing. Extracts RR intervals from camera frames for heart rate and HRV analysis.
Flutter PPG (Photoplethysmography) #
A Flutter package for real-time camera-based PPG (Photoplethysmography) signal processing. This package extracts the raw red channel intensity from camera frames, filters the signal to isolate cardiac activity, and detects heartbeats (RR intervals).
⚠️ Requirements #
- Hardware: A device with a Camera and a Flash (Torch).
- Platform: iOS or Android (Real device required, Simulator/Emulator usually cannot provide camera/flash access).
🚀 Getting Started #
1. Installation #
Add flutter_ppg to your pubspec.yaml:
dependencies:
flutter_ppg:
path: ../ # Or your git/pub path
2. Basic Usage #
Use the FlutterPPGService to process a stream of CameraImages from the camera package.
// 1. Initialize Service
final ppgService = FlutterPPGService();
// 2. Start Camera Image Stream
// (Assuming standard camera controller setup)
controller.startImageStream((CameraImage image) {
// Bridge to stream if necessary, or just use the service directly if updated
});
// Since the current API expects a Stream<CameraImage>, you can use a StreamController:
final streamController = StreamController<CameraImage>();
controller.startImageStream((image) => streamController.add(image));
// 3. Process Stream
ppgService.processImageStream(streamController.stream).listen((PPGSignal signal) {
print('Quality: ${signal.quality}');
print('Filtered Value: ${signal.filteredIntensity}');
if (signal.rrIntervals.isNotEmpty) {
print('Last RR: ${signal.rrIntervals.last} ms');
}
});
// Remember to dispose when done:
// streamController.close();
// ppgService.dispose();
See the example/ directory for a complete working application.
3. Custom Configuration (PPGConfig) #
You can override thresholds and timing using PPGConfig:
final config = PPGConfig(
samplingRate: 30,
windowSizeSeconds: 10,
minRRMs: 300.0,
maxRRMs: 2000.0,
maxAdjacentRRChangeRatio: 0.30,
maxAcceptableSDRRMs: 150.0,
maxDriftRate: 50.0,
minGoodSNR: 5.0,
minFairSNR: 0.0,
fingerPresenceMin: 30.0,
fingerPresenceMax: 250.0,
);
final ppgService = FlutterPPGService(config: config);
Override Priority (SSOT rules):
- If you pass custom instances (
qualityAssessor,outlierFilter,rrIntervalAnalyzer,peakDetector), those overridePPGConfigvalues for their respective behavior. - If you do not pass a custom instance,
FlutterPPGServicebuilds it fromPPGConfig. - If you pass a custom
PeakDetector, adaptive min-distance (FPS-based) is not applied.
4. Recommended Measurement Flow (Client-side) #
The library emits raw metrics every frame. Session control (warm-up, duration, acceptance) should live in your app, not inside the package.
Suggested gating logic:
- Ignore the first ~10 seconds (warm-up)
- Require
signal.isFPSStable == true - Require
signal.rejectionRatio <= 0.20 - Require
signal.isSDRRAcceptable == true
Note: when isFPSStable is false, the package skips RR interval generation
and emits empty rrIntervals for that frame.
Example (pseudo):
if (signal.isFPSStable &&
signal.rejectionRatio <= 0.20 &&
signal.isSDRRAcceptable &&
signal.quality != SignalQuality.poor) {
// Accept this signal for BPM/HRV calculation
}
5. Operational Notes (Recommended) #
These are practical guidelines for more stable measurements in real apps:
- Low FPS segments: if
signal.frameRatedrops significantly (e.g., <20 FPS), discard those samples from BPM/HRV aggregation. - isFPSStable behavior: stability requires sustained FPS above a minimum threshold
(internally, consecutive low-FPS updates will set
isFPSStable=false). - Recommended measurement duration: 30–60 seconds yields more stable HRV metrics.
- UI load matters: heavy animations or frequent setState can reduce FPS and degrade signal quality.
- Finger placement: cover both lens and flash; minimize motion and pressure changes.
- FPS stability: frame rate is estimated from a monotonic clock to reduce wall-clock jitter.
- Logging (optional): for debugging, capture at least:
frameRate,isFPSStable,quality,snrsdrr,rejectionRatio,driftRate- raw/filtered mean + range over a short window
Adaptive prominence details (current defaults):
minProminence = max(0.2, 0.5 * stddev)computed from the last ~60 filtered samples- The detector is updated only when the prominence changes by ≥ 0.05
- If there is not enough data, the base
PeakDetector.minProminenceis used
👆 How to Measure #
For accurate readings in the example app (or your implementation):
- Enable Flash: The back camera flash MUST be on (
FlashMode.torch). - Cover Lens & Flash: Place your fingertip gently over both the camera lens and the flash.
- Do not press too hard (this restricts blood flow).
- Do not press too ligthly (ambient light leaks in).
- Stay Still: Motion introduces significant noise. Keep your finger and the phone steady.
📦 Features #
- Signal Processing:
- Red channel extraction (optimized for YUV420/BGRA8888).
- Simple bandpass approximation (SMA short - SMA long) to isolate pulse band.
- Detrending helper available (not wired into the current pipeline).
- Peak Detection:
- Robust local maxima detection with minimum distance enforcement.
- Outlier rejection (IQR method) for cleaner RR intervals.
- Adaptive prominence based on recent filtered signal variability.
- Quality Assessment:
- Real-time Signal Quality Index (Good/Fair/Poor).
- Finger presence detection based on light intensity.
- SNR-based quality evaluation.
🧩 Architecture #
The package follows clean architecture principles:
SignalProcessor: Pure logic for math and filtering (Stateless).PeakDetector: Algorithms for identifying heartbeats.SignalQualityAssessor: Heuristics for signal validity.FlutterPPGService: Orchestrator (Stateful) managing the data flow and buffers.
✅ Current Defaults / Planned Thresholds (Confirm in Refactor) #
Current defaults (v0.1.x):
- Sampling rate: 30 FPS (
PPGConfig.samplingRate) - Window size: 10 seconds (
PPGConfig.windowSizeSeconds) - Peak min distance: derived from
PPGConfig.minRRMs+ FPS - Peak min prominence: 0.5 (
PeakDetector.minProminence) - RR physiological range: 300–2000ms (
PPGConfig.minRRMs/maxRRMs) - Finger presence: 30–250 intensity (
PPGConfig.fingerPresenceMin/fingerPresenceMax) - SNR quality: >5 dB = good, >0 dB = fair (
PPGConfig.minGoodSNR/minFairSNR)
Planned thresholds (v0.2.x, needs agreement):
- Max adjacent RR change: 30% (
PPGConfig.maxAdjacentRRChangeRatio) - Max acceptable SDRR: 150ms (
PPGConfig.maxAcceptableSDRRMs) - Max baseline drift: 50 intensity units/sec (
PPGConfig.maxDriftRate) - Frame-rate auto detection: 24/25/30/60 FPS + adaptive timing windows
Notes:
- "Intensity" is derived from camera pixel data (0–255-ish scale).
- Once FPS detection is added, time-based windows/min-distance will be derived from actual FPS.
📝 License #