Introduction
This is a set of packages implementing Modbus Client sending requests to a remote device (i.e. Modbus Server).
- Modbus Client is the base implementation for the TCP/UDP and Serial packages.
- Modbus Client TCP implements the TCP protocol to send requests via ethernet networks.
- Modbus Client UDP implements the UDP protocol to send requests via ethernet networks.
- Modbus Client Serial implements the ASCII and RTU protocols to send requests via Serial Port
The split of the packages is done to minimize dependencies on your project.
Notes for serial implementation
- For Flutter projects: you only need to add flutter_libserialport package to your own project (i.e. run flutter pub add flutter_libserialport)
- For Dart projects: you need to build the serial library libserialport build instructions. As a workaround you can create a dummy Flutter project, add the flutter_libserialport package, build it and copy the auto-generated serialport library from the build folder into your project's root folder or wherever your binary code will run.
Features
- Auto connection mode: specify how the send command behaves by auto connecting and auto disconnecting from the client by setting the ModbusConnectionMode
- Unit id: both the Modbus Client and the Request can specify the target unit id. This can be useful when using serial clients where more units/devices can be attached to one serial client.
- Response timeout: A timeout waiting the response can be set in the Modbus Client instance or in the Request itself.
- Server discovery (TCP only): discovers the modbus server from a starting IP address Modbus Client TCP.
- Connection timeout (TCP only): specify a connection timeout for the Modbus Client TCP.
- Delay after connect (TCP only): you can apply an optional delay after server connection. In some cases (e.g. Huawei SUN2000 inverter) the server will not respond if requests are sent right after the connection.
- Element types: this package offers a variety of element types: ModbusNumRegister (int16, uint16, int32, uint32, int64, uint64, float and double), ModbusBitElement, ModbusEnumRegister, ModbusStatusRegister, ModbusBitMaskRegister, ModbusEpochRegister, ModbusBytesRegister.
- File records: support File Records function code 0x14 and 0x15 of different types of numeric records (int16, uint16, int32, uint32, float and double).
- Endianness: Define how bytes are arranged in the modbus register.
- ABCD(swapWord: false, swapByte: false)
- CDAB(swapWord: true, swapByte: false)
- BADC(swapWord: false, swapByte: true)
- DCBA(swapWord: true, swapByte: true)
- Group of elements: in order to optimize request you can create group of elements.
- Custom requests implementation: you can easily implement custom request by overriding the Request class, assigning the request PDU (i.e. the protocolDataUnit) and override the internalSetFromPduResponse method or you override the Element Request class by overriding the internalSetElementData method.
- Logging: Modbus Client libraries have logging enabled. You can activate logging with the root logger or by creating a ModbusAppLogger instance in your app.
Usage
Using modbus client is simple. You define your elements, create a read or write request out of them and use the client to send the request.
Read Request
import 'package:modbus_client/modbus_client.dart';
import 'package:modbus_client_tcp/modbus_client_tcp.dart';
void main() async {
// Create a modbus int16 register element
var batteryTemperature = ModbusInt16Register(
name: "BatteryTemperature",
type: ModbusElementType.inputRegister,
address: 22,
uom: "°C",
multiplier: 0.1,
onUpdate: (self) => print(self));
// Discover the Modbus server
var serverIp = await ModbusClientTcp.discover("192.168.0.0");
if (serverIp == null) {
ModbusAppLogger.shout("No modbus server found!");
return;
}
// Create the modbus client.
var modbusClient = ModbusClientTcp(serverIp, unitId: 1);
// Send a read request from the element
await modbusClient.send(batteryTemperature.getReadRequest());
// Ending here
modbusClient.disconnect();
}
Write Request
import 'package:modbus_client/modbus_client.dart';
import 'package:modbus_client_tcp/modbus_client_tcp.dart';
enum BatteryStatus implements ModbusIntEnum {
offline(0),
standby(1),
running(2),
fault(3),
sleepMode(4);
const BatteryStatus(this.intValue);
@override
final int intValue;
@override
String toString() {
return name;
}
}
void main() async {
var batteryStatus = ModbusEnumRegister(
name: "BatteryStatus",
address: 11,
type: ModbusElementType.holdingRegister,
enumValues: BatteryStatus.values,
onUpdate: (self) => print(self));
// Discover the Modbus server
var serverIp = await ModbusClientTcp.discover("192.168.0.0");
if (serverIp == null) {
ModbusAppLogger.shout("No modbus server found!");
return;
}
// Create the modbus client.
var modbusClient = ModbusClientTcp(serverIp, unitId: 1);
var req = batteryStatus.getWriteRequest(BatteryStatus.running);
var res = await modbusClient.send(req);
print(res.name);
modbusClient.disconnect();
}
Modbus Elements
This library has a wide range of defined modbus elements having a name, a description, a modbus address and an update callback you can use in case the element value has been updated.
Bit and Numeric Elements
Typical elements are simple bit and numeric values:
- ModbusDiscreteInput
- ModbusCoil
- ModbusInt16Register
- ModbusUint16Register
- ModbusInt32Register
- ModbusUint32Register
- ModbusInt64Register
- ModbusUint64Register
- ModbusFloatRegister
- ModbusDoubleRegister
Numeric elements have an uom (i.e. unit of measure), a multiplier and offset to make conversion from raw to engineering values (i.e. value = read_value*multiplier + offset), and viewDecimalPlaces to print out only needed decimals.
Enum Element
To read and write an enum as an element you can use a ModbusEnumRegister
/// Implement [ModbusIntEnum] to use it with a [ModbusEnumRegister]
enum BatteryStatus implements ModbusIntEnum {
offline(0),
standby(1),
running(2),
fault(3),
sleepMode(4);
const BatteryStatus(this.intValue);
@override
final int intValue;
@override
String toString() {
return name;
}
}
void main() async {
ModbusAppLogger(Level.FINEST);
var batteryStatus = ModbusEnumRegister(
name: "BatteryStatus",
address: 11,
type: ModbusElementType.holdingRegister,
enumValues: BatteryStatus.values);
var modbusClient = ModbusClientTcp("127.0.0.1", unitId: 1);
await modbusClient.send(batteryStatus.getReadRequest());
modbusClient.disconnect();
}
Status Element
Similar to enum is a status element. Within a ModbusStatusRegister you can define all the possible statues (i.e. numeric <-> string pairs) for the element.
ModbusStatusRegister(
name: "Device status",
type: ModbusElementType.holdingRegister,
address: 32089,
statusValues: [
ModbusStatus(0x0000, "Standby: initializing"),
ModbusStatus(0x0001, "Standby: detecting insulation resistance"),
ModbusStatus(0x0002, "Standby: detecting irradiation"),
ModbusStatus(0x0003, "Standby: drid detecting"),
ModbusStatus(0x0100, "Starting"),
ModbusStatus(0x0200, "On-grid (Off-grid mode: running)"),
ModbusStatus(0x0201,
"Grid connection: power limited (Off-grid mode: running: power limited)"),
ModbusStatus(0x0202,
"Grid connection: selfderating (Off-grid mode: running: selfderating)"),
ModbusStatus(0x0203, "Off-grid Running"),
ModbusStatus(0x0300, "Shutdown: fault"),
ModbusStatus(0x0301, "Shutdown: command"),
ModbusStatus(0x0302, "Shutdown: OVGR"),
ModbusStatus(0x0303, "Shutdown: communication disconnected"),
ModbusStatus(0x0304, "Shutdown: power limited"),
ModbusStatus(0x0305, "Shutdown: manual startup required"),
ModbusStatus(0x0306, "Shutdown: DC switches disconnected"),
ModbusStatus(0x0307, "Shutdown: rapid cutoff"),
ModbusStatus(0x0308, "Shutdown: input underpower"),
ModbusStatus(0x0401, "Grid scheduling: cosφ-P curve"),
ModbusStatus(0x0402, "Grid scheduling: Q-U curve"),
ModbusStatus(0x0403, "Grid scheduling: PF-U curve"),
ModbusStatus(0x0404, "Grid scheduling: dry contact"),
ModbusStatus(0x0405, "Grid scheduling: Q-P curve"),
ModbusStatus(0x0500, "Spotcheck ready"),
ModbusStatus(0x0501, "Spotchecking"),
ModbusStatus(0x0600, "Inspecting"),
ModbusStatus(0X0700, "AFCI self check"),
ModbusStatus(0X0800, "I-V scanning"),
ModbusStatus(0X0900, "DC input detection"),
ModbusStatus(0X0A00, "Running: off-grid charging"),
ModbusStatus(0xA000, "Standby: no irradiation"),
]),
Bit Mask Element
Use ModbusBitMaskRegister if your device has registers where each bit value has a special meaning. You can define both an active and inactive value for each ModbusBitMask object.
ModbusBitMaskRegister(
name: "Alarm 1",
type: ModbusElementType.holdingRegister,
address: 32008,
bitMasks: [
ModbusBitMask(0, "High String Input Voltage [2001 Major]"),
ModbusBitMask(1, "DC Arc Fault [2002 Major]"),
ModbusBitMask(2, "String Reverse Connection [2011 Major]"),
ModbusBitMask(3, "String Current Backfeed [2012 Warning]"),
ModbusBitMask(4, "Abnormal String Power [2013 Warning]"),
ModbusBitMask(5, "AFCI Self-Check Fail. [2021 Major]"),
ModbusBitMask(6, "Phase Wire Short-Circuited to PE [2031 Major]"),
ModbusBitMask(7, "Grid Loss [2032 Major]"),
ModbusBitMask(8, "Grid Undervoltage [2033 Major]"),
ModbusBitMask(9, "Grid Overvoltage [2034 Major]"),
ModbusBitMask(10, "Grid Volt. Imbalance [2035 Major]"),
ModbusBitMask(11, "Grid Overfrequency [2036 Major]"),
ModbusBitMask(12, "Grid Underfrequency [2037 Major]"),
ModbusBitMask(13, "Unstable Grid Frequency [2038 Major]"),
ModbusBitMask(14, "Output Overcurrent [2039 Major]"),
ModbusBitMask(15, "Output DC Component Overhigh [2040 Major]"),
]),
Epoch/DateTime Element
Use ModbusEpochRegister if your device holds timestamp values as Epoch/Unix time in seconds.
ModbusEpochRegister(
name: "Startup time",
type: ModbusElementType.holdingRegister,
address: 32091,
isUtc: false);
Epoch/DateTime Element
Use ModbusEpochRegister if your device holds timestamp values as Epoch/Unix time in seconds.
ModbusEpochRegister(
name: "Startup time",
type: ModbusElementType.holdingRegister,
address: 32091,
isUtc: false);
Bytes Array Element
Use ModbusBytesRegister if you want to read and write multiple bytes/registers at a time. Note that byteCount cannot exceed 250 bytes which is the multiple read bytes limit for Modbus/RTU. Note that the protocol limit depends on multiple factors:
- Read & Write have different limits
- Modbus RTU and TCP have different limits
- Device dependent limits To get the right limit please refer to Modbus specs and your device manual.
var bytesRegister = ModbusBytesRegister(
name: "BytesArray",
address: 4,
byteCount: 10,
onUpdate: (self) => print(self));
// Create the modbus client.
var modbusClient = ModbusClientTcp("127.0.0.1", unitId: 1);
var req1 = bytesRegister.getWriteRequest(Uint8List.fromList(
[0x01, 0x02, 0x03, 0x04, 0x05, 0x66, 0x07, 0x08, 0x09, 0x0A]));
var res = await modbusClient.send(req1);
print(res);
var req2 = bytesRegister.getReadRequest();
res = await modbusClient.send(req2);
print(bytesRegister.value);
modbusClient.disconnect();
Element Group
You can define a ModbusElementsGroup to optimize the elements reading. The most the element addresses are contiguous the most performant is the request. The address range limit for bits is 2000 and 125 for registers. You can use the ModbusElementsGroup object as a kind of list of element.
import 'package:modbus_client/modbus_client.dart';
import 'package:modbus_client_tcp/modbus_client_tcp.dart';
enum BatteryStatus implements ModbusIntEnum {
offline(0),
standby(1),
running(2),
fault(3),
sleepMode(4);
const BatteryStatus(this.intValue);
@override
final int intValue;
}
void main() async {
// Create a modbus elements group
var batteryRegs = ModbusElementsGroup([
ModbusEnumRegister(
name: "BatteryStatus",
type: ModbusElementType.holdingRegister,
address: 37000,
enumValues: BatteryStatus.values),
ModbusInt32Register(
name: "BatteryChargingPower",
type: ModbusElementType.holdingRegister,
address: 37001,
uom: "W",
description: "> 0: charging - < 0: discharging"),
ModbusUint16Register(
name: "BatteryCharge",
type: ModbusElementType.holdingRegister,
address: 37004,
uom: "%",
multiplier: 0.1),
ModbusUint16Register(
name: "BatteryTemperature",
type: ModbusElementType.holdingRegister,
address: 37022,
uom: "°C",
multiplier: 0.1),
]);
// Create the modbus client.
var modbusClient = ModbusClientTcp("127.0.0.1", unitId: 1);
// Send a read request from the group
await modbusClient.send(batteryRegs.getReadRequest());
print(batteryRegs[0]);
print(batteryRegs[1]);
print(batteryRegs[2]);
print(batteryRegs[3]);
// Ending here
modbusClient.disconnect();
}
Modbus File Records
This library supports function codes 0x14 and 0x15 to read and write different types of numeric records.
File Record Types
- ModbusFileInt16Record
- ModbusFileUint16Record
- ModbusFileInt32Record
- ModbusFileUint32Record
- ModbusFileFloatRecord
- ModbusFileDoubleRecord
- ModbusFileMultipleRecord
import 'dart:typed_data';
import 'package:logging/logging.dart';
import 'package:modbus_client/modbus_client.dart';
import 'package:modbus_client_tcp/modbus_client_tcp.dart';
void main() async {
// Simple modbus logging
ModbusAppLogger(Level.FINE);
// Create the modbus client.
var modbusClient = ModbusClientTcp("127.0.0.1", unitId: 1);
// Write two file records
var r1 = ModbusFileUint16Record(
fileNumber: 4,
recordNumber: 1,
recordData: Uint16List.fromList([12573, 56312]));
var r2 = ModbusFileDoubleRecord(
fileNumber: 3,
recordNumber: 9,
recordData: Float64List.fromList([123.5634, 125756782.8492]));
await modbusClient.send(ModbusFileRecordsWriteRequest([r1, r2]));
// Read two file records
r1 = ModbusFileUint16Record.empty(
fileNumber: 4, recordNumber: 1, recordDataCount: 2);
r2 = ModbusFileDoubleRecord.empty(
fileNumber: 3, recordNumber: 9, recordDataCount: 2);
await modbusClient.send(ModbusFileRecordsReadRequest([r1, r2]));
// Write multiple records
var multipleRecords =
ModbusFileMultipleRecord(fileNumber: 4, recordNumber: 1);
multipleRecords.addNext(ModbusRecordType.int16, -123);
multipleRecords.addNext(ModbusRecordType.uint16, 5000);
multipleRecords.addNext(ModbusRecordType.int32, -1234567890);
multipleRecords.addNext(ModbusRecordType.uint32, 1234567890);
multipleRecords.addNext(ModbusRecordType.float, 123.45);
multipleRecords.addNext(ModbusRecordType.double, 12345.6789);
await modbusClient.send(multipleRecords.getWriteRequest());
multipleRecords = ModbusFileMultipleRecord.empty(
fileNumber: 4, recordNumber: 1, recordDataByteLength: 24);
await modbusClient.send(multipleRecords.getReadRequest());
multipleRecords.start();
print(multipleRecords.getNext(ModbusRecordType.int16));
print(multipleRecords.getNext(ModbusRecordType.uint16));
print(multipleRecords.getNext(ModbusRecordType.int32));
print(multipleRecords.getNext(ModbusRecordType.uint32));
print(multipleRecords.getNext(ModbusRecordType.float));
print(multipleRecords.getNext(ModbusRecordType.double));
// Ending here
modbusClient.disconnect();
}